Delta Electronics 6740B & 6742B 3-1/8″ EIA Coaxial Transfer Switch

Delta electronics Logo

Summary

Introduction

The Model 6740B and Model 6742B Coaxial Transfer Switches are double-pole, double throw, high power switches for use with 3-1/8 inch 50 Ohm transmission line. The manually or remotely operated transfer switches enable the changing of coaxial connections between transmitters and antennas/dummy loads with a minimum of changeover or off-air-time. Transmission line switching occurs in less than two seconds. The Model 6740B operates with 120 VAC, 50/60 Hz main power and the Model 6742B operates with 220/240 VAC, 50/60 Hz main power.

Description

Coaxial transfer switches are used to switch transmitters, transmission lines, antennas, dummy loads and auxiliary equipment quickly and efficiently when failures occur, when operating procedures are changed, or during scheduled maintenance periods. They also simplify equipment tuning, testing, and emergency repairs by facilitating quick checks under actual operating conditions.

Many switching requirements in a station are greatly reduced by the use of transfer switches. In complex systems, only one-third or one-fourth as many transfer switches are needed to accomplish the same switching function as a system using SPDT or SP3T type switches. If only three of the terminals in the Model 6740B or 6742B switch are employed, the switch can be used as a SPDT type.

Features

The Models 6740B and 6742B can be pressurized up to 15 lb/sq in (1.1 kg/sq cm). A gas barrier is built into each terminal and an air inlet port is provided.

The Coaxial Transfer Switch provides two isolated interlock circuits for each switch connection that duplicate the RF path exactly. All interlock switches open before the RF contacts open, and close after the RF contacts close to prevent switching with RF power applied. Additional internal switch contacts enable remote control and status indication. All interlock, indicator and control circuits interface the transfer switch through a connector.

The transfer switch can be remotely controlled using either a high level, direct AC main power switching interface or a low level, open collector/contact closure interface. The Model 33630A Coaxial Switch Control Panel controls either a Model 6740B or Model 6742B Coaxial Transfer Switch and indicates the switch connections. The control panel operates with 120 VAC or 220/240 VAC, 50/60 Hz main power and mounts in a standard equipment rack space of 3-1/2″ high by 19″ wide.

Model 33630A Coaxial Switch Control Panel

Optionally, the transfer switch can be supplied with internal relays to provide an open collector or contact closure interface for low level control applications. The low level control signal needs to be maintained only for the duration of the switching cycle. Low level interface relays for operation with either 12, 24 or 48 VDC control circuits are available. Consult the factory with your requirements.

 

Technical Specification

>h2>Technical Specification</h2>

 

Model Number 6740B 6742B

Termination, Male EIA Flange: 3-1/8 in 3-1/8 in
Frequency Range, MHz: 0-216⇔ 0-216⇔
Impedance, Ohms: 50 50
Average Power Rating*, kW:
@ 50 MHz
@ 108 MHz
@ 216 MHz
70
47.6
30
70
47.6
30
Peak Power Rating*, kW: 400 400
VSWR, Guaranteed Maximum: 1.04 1.04
Isolation, Typical, dB: 60 60
Insertion Loss, dB: 0.1 0.1
Switching Time, Maximum, Seconds: 2 2
Pressurization Yes, 15 lbs/sq in Yes, 15 lbs/sq in
Power Source: 120 VAC ±10%,
50/60 Hz
220/240 VAC ±5%,
50/60 Hz
Optional Interface Relay Operation Power, Nominal, Watts: 1 1
Power Drain, Watts (during switching): 200 200
Interlock Contact Rating:
@ 24 VDC/120 VAC@ 240 VAC
7 Amps Res,
5 Amps Ind
6 Amps Res,
4 Amps Ind
7 Amps Res,
5 Amps Ind
6 Amps Res,
4 Amps Ind
Dimensions:
(L x W x D)
Inches
mm
14 x 14 x 14
360 x 360 x 360
14 x 14 x 14
360 x 360 x 360
Weight:
Pounds
kg
65
35
65
35
Order Numbers:
  Switch with 4 standard
3-1/8″ EIA connectors
961-0022-001 961-0022-002
  Model 33630A Coaxial
Switch Control Panel
913-0069-001 913-0069-002

Low Level Interface Relays 12 VDC 24 VDC 48 VDC
   Factory Modification Kit 942-0092-001 942-0092-002 942-0092-003
   Field Modification Kit 942-0103-001 942-0103-002 942-0103-003

* At unity VSWR and 40° C (104° F) ambient temperature.
Model 6740B/6742B switches may be used at frequencies above 216 MHz with derating of average power, VSWR, isolation and insertion loss specifications. Consult the factory with your requirements.

Product Resources